| Decontaminating and cooling pocess of up-stage gas:Up-stage gas fistly gets into electrical detarrer (|) whose work temperature is about 90-150℃.In this part,heavy tar and dust are separated.Up-stage gas then gets into indirect cooler,where the gas is cooled to 35-45℃.Firstly,dust is centrifugally separated from down-stage gas and gas temperature is lowered to about 450-500℃;secondly,the gas comes into e4xhaust heating boiler to recove the gas sensible heat with the temperature dropping to about 180-220℃;thirdly,the gas temperature is dropped to 65-80℃ in forced wind cooler; and finally,its temperature is lowered to 35-45℃ by circulatory cooling water in indirect cooler.Then the up-stage gas is mixed with up-stage gas and gets into electrical deoiler (||) go have a second removing of oil and dust.The gas through dealing is pressed by pressure adder,separeted gas moisture by trap for water and finally supply to the user.
Technical systematic drawing of down stage gas Technical systematic drawing of up stage gas
 |